Energy spread estimation of radioactive oxygen ion beams using optical imaging

Han Gyu Kang*, Seiichi Yamamoto, Sodai Takyu, Fumihiko Nishikido, Akram Mohammadi, Go Akamatsua, Shinji Sato, Taiga Yamaya

*この研究の対応する著者

研究成果: Article査読

1 被引用数 (Scopus)

抄録

Radioactive ion (RI) beams combined with in-beam positron emission tomography enable accurate in situ beam range verification in heavy ion therapy. However, the energy spread of the radioactive beams generated as secondary beams is wider than that of conventional stable heavy ion beams which causes Bragg peak region and distal falloff region broadening. Therefore, the energy spread of the RI beams should be measured carefully for their quality control. Here, we proposed an optical imaging technique for the energy spread estimation of radioactive oxygen ion beams. A polymethyl methacrylate phantom (10.0 × 10.0 × 9.9 cm3) was irradiated with an 15O beam (mean energy = 247.7 MeV u1, standard deviation = 6.8 MeV u1) in the Heavy Ion Medical Accelerator in Chiba. Three different momentum acceptances of 1%, 2% and 4% were used to get energy spreads of 1.9 MeV u1, 3.4 MeV u1 and 5.5 MeV u1, respectively. The in-beam luminescence light and offline beam Cerenkov light images were acquired with an optical system consisting of a lens and a cooled charge-coupled device camera. To estimate the energy spread of the 15O ion beams, we proposed three optical parameters: (1) distal-50% falloff length of the prompt luminescence signals; (2) full-width at half maximum of the Cerenkov light signals in the beam direction; and (3) positional difference between the peaks of the Cerenkov light and the luminescence signals. These parameters estimated the energy spread with the respective mean squared errors of 2.52 × 103 MeV u1, 5.91 × 103 MeV u1, and 0.182 MeV u1. The distal-50% falloff length of the luminescence signals provided the lowest mean squared error among the optical parameters. From the findings, we concluded optical imaging using luminescence and Cerenkov light signals offers an accurate energy spread estimation of 15O ion beams. In the future, the proposed optical parameters will be used for energy spread estimation of other RI beams as well as stable ion beams.

本文言語English
論文番号235002
ジャーナルPhysics in Medicine and Biology
65
23
DOI
出版ステータスPublished - 2020 11月 25
外部発表はい

ASJC Scopus subject areas

  • 放射線技術および超音波技術
  • 放射線学、核医学およびイメージング

フィンガープリント

「Energy spread estimation of radioactive oxygen ion beams using optical imaging」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル