@inproceedings{7ff2888592574e4f867c24c913baa208,
title = "Estimation of external corrosion under insulation using Group numbering of continuous conditions",
abstract = "External corrosion of pipes in chemical and petrochemical plants is developing very slowly therefore corrosion of pipes has been disregarded as maintenance objects. However, many pipes are considerably corroded on the outside surface because many plants in Japan have been operated for 30 years or more. Accidents which relate to corrosions sometimes occurred and led to serious problems and vast losses. Corrosion under insulation (CUI) is extremely difficult to be detected and quantified. The purpose of this research is to estimate CUI potential and corrosion rates by using case database and Group numbering of the continuous condition.",
keywords = "CUI, corrosion rate, database modeling, maintenance",
author = "Kentaro Yahiro and Sunghye Moon and Shigeyuki Tateno and Hisayoshi Matsuyama",
year = "2011",
month = jan,
day = "1",
language = "English",
isbn = "9784907764395",
series = "Proceedings of the SICE Annual Conference",
publisher = "Society of Instrument and Control Engineers (SICE)",
pages = "2893--2898",
booktitle = "SICE 2011 - SICE Annual Conference 2011, Final Program and Abstracts",
note = "50th Annual Conference on Society of Instrument and Control Engineers, SICE 2011 ; Conference date: 13-09-2011 Through 18-09-2011",
}