抄録
This paper describes a method for measuring non-uniform thermal environments using a new thermal manikin with controlled skin surface temperature. The manikin and its control logic are described, and an equivalent temperature based on the thermal manikin (teq) is proposed and discussed. A method to calculate the PMV index from manikin heat loss is also given. To calibrate these methods, fundamental data were collected. The manikin-based equivalent temperature (teq) is shown to be effective at accounting for the effects of local heat sources and asymmetrical environmental conditions.
本文言語 | English |
---|---|
ページ(範囲) | 39-48 |
ページ数 | 10 |
ジャーナル | ASHRAE Transactions |
巻 | 100 |
号 | 1 |
出版ステータス | Published - 1994 |
外部発表 | はい |
イベント | Proceedings of the ASHRAE Winter Meeting - New Orleans, LA, USA 継続期間: 1994 1月 23 → 1994 1月 26 |
ASJC Scopus subject areas
- 建築および建設
- 機械工学