TY - JOUR
T1 - FEM modeling of the towers in Bayon temple in Cambodia based on micro-tremor measurements
AU - Maeda, Toshiro
AU - Sugiura, Yoshikazu
AU - Hirai, Tomonari
PY - 2008/4
Y1 - 2008/4
N2 - Bayon temple, Angkor, Cambodia, built in 13th century, is a dry-masonry temple made of sandstone which has deteriorated possibly due to rain, plants, settlements, and so on. Moreover, we may add wind induced direct or via-ground vibration to the list of deterioration causes since strong winds of more than 20 m/s was observed, which will require us to evaluate structural responses to the wind excitation. Based on micro-tremor measurements, we identified predominant frequencies, damping factors and base-fixed frequencies of the main tower and sub-towers in the temple and neighboring Prasat Sour Prat towers; FEM models were constructed by simulating the base-fixed natural frequencies of the horizontal translational modes. During the simulation, we had to reduce the elastic modulus of sandstone to less than 1/10 of typical value, which may suggest that the continuum modeling of dry-masonry structures is inappropriate.
AB - Bayon temple, Angkor, Cambodia, built in 13th century, is a dry-masonry temple made of sandstone which has deteriorated possibly due to rain, plants, settlements, and so on. Moreover, we may add wind induced direct or via-ground vibration to the list of deterioration causes since strong winds of more than 20 m/s was observed, which will require us to evaluate structural responses to the wind excitation. Based on micro-tremor measurements, we identified predominant frequencies, damping factors and base-fixed frequencies of the main tower and sub-towers in the temple and neighboring Prasat Sour Prat towers; FEM models were constructed by simulating the base-fixed natural frequencies of the horizontal translational modes. During the simulation, we had to reduce the elastic modulus of sandstone to less than 1/10 of typical value, which may suggest that the continuum modeling of dry-masonry structures is inappropriate.
KW - Bayon temple
KW - Dry-masonry
KW - FEM
KW - Historical architecture
KW - Micro-tremor
KW - Prasat Sour Prat
UR - http://www.scopus.com/inward/record.url?scp=37349022843&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=37349022843&partnerID=8YFLogxK
U2 - 10.1016/j.advengsoft.2007.01.007
DO - 10.1016/j.advengsoft.2007.01.007
M3 - Article
AN - SCOPUS:37349022843
SN - 0965-9978
VL - 39
SP - 346
EP - 355
JO - Advances in Engineering Software
JF - Advances in Engineering Software
IS - 4
ER -