TY - JOUR
T1 - Field effect transistor biosensor using antigen binding fragment for detecting tumor marker in human serum
AU - Cheng, Shanshan
AU - Hotani, Kaori
AU - Hideshima, Sho
AU - Kuroiwa, Shigeki
AU - Nakanishi, Takuya
AU - Hashimoto, Masahiro
AU - Mori, Yasuro
AU - Osaka, Tetsuya
PY - 2014
Y1 - 2014
N2 - Detection of tumor markers is important for cancer diagnosis. Field-effect transistors (FETs) are a promising method for the label-free detection of trace amounts of biomolecules. However, detection of electrically charged proteins using antibody-immobilized FETs is limited by ionic screening by the large probe molecules adsorbed to the transistor gate surface, reducing sensor responsiveness. Here, we investigated the effect of probe molecule size on the detection of a tumor marker, α-fetoprotein (AFP) using a FET biosensor. We demonstrated that the small receptor antigen binding fragment (Fab), immobilized on a sensing surface as small as 2-3 nm, offers a higher degree of sensitivity and a wider concentration range (100 pg/mL-1 μg/mL) for the FET detection of AFP in buffer solution, compared to the whole antibody. Therefore, the use of a small Fab probe molecule instead of a whole antibody is shown to be effective for improving the sensitivity of AFP detection in FET biosensors. Furthermore, we also demonstrated that a Fab-immobilized FET subjected to a blocking treatment, to avoid non-specific interactions, could sensitively and selectively detect AFP in human serum.
AB - Detection of tumor markers is important for cancer diagnosis. Field-effect transistors (FETs) are a promising method for the label-free detection of trace amounts of biomolecules. However, detection of electrically charged proteins using antibody-immobilized FETs is limited by ionic screening by the large probe molecules adsorbed to the transistor gate surface, reducing sensor responsiveness. Here, we investigated the effect of probe molecule size on the detection of a tumor marker, α-fetoprotein (AFP) using a FET biosensor. We demonstrated that the small receptor antigen binding fragment (Fab), immobilized on a sensing surface as small as 2-3 nm, offers a higher degree of sensitivity and a wider concentration range (100 pg/mL-1 μg/mL) for the FET detection of AFP in buffer solution, compared to the whole antibody. Therefore, the use of a small Fab probe molecule instead of a whole antibody is shown to be effective for improving the sensitivity of AFP detection in FET biosensors. Furthermore, we also demonstrated that a Fab-immobilized FET subjected to a blocking treatment, to avoid non-specific interactions, could sensitively and selectively detect AFP in human serum.
KW - Antigen binding fragment
KW - Field effect transistor
KW - Immunosensor
KW - Label-free detection
KW - Langmuir-type adsorption model
UR - http://www.scopus.com/inward/record.url?scp=84899145018&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84899145018&partnerID=8YFLogxK
U2 - 10.3390/ma7042490
DO - 10.3390/ma7042490
M3 - Article
AN - SCOPUS:84899145018
SN - 1996-1944
VL - 7
SP - 2490
EP - 2500
JO - Materials
JF - Materials
IS - 4
ER -