Fire resistance of Japanese traditional timber-frame soil internal walls exposed to both-sides heating

Yoshinao Sawano*, Yuji Hasemi, Noboru Yasui, Atsushi Ogawa, Hiroyuki Hirai, Tadanori Kimura, Koichi Yamamoto

*この研究の対応する著者

研究成果: Article査読

1 被引用数 (Scopus)

抄録

Mechanical fire resistance of internal load bearing walls under both-sides heating is important for the prevention of collapse of a dwelling in a fire. Feasibility of the 45 minutes mechanical fire resistance with Japanese traditional timber-frame soil internal wall is studied for this purpose. The tests were initiated with intermediate scale specimens for the examination of the charring and internal temperature field of the column and then loaded tests under both-sides exposure were conducted on two 1-story tall bare-timber wall specimens. The tests suggest significant influence of the mortises of columns for horizontal timber bars on the buckling of walls. The conventional predictive method of the mechanical fire resistance of bare timber walls is then modified for the tested configuration.

本文言語English
ページ(範囲)1-7
ページ数7
ジャーナルJournal of Environmental Engineering
74
635
DOI
出版ステータスPublished - 2009 1月

ASJC Scopus subject areas

  • 環境工学

フィンガープリント

「Fire resistance of Japanese traditional timber-frame soil internal walls exposed to both-sides heating」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。