Heating mechanism of unprotected steel beam installed beneath ceiling and exposed to a localized fire: Verification using the real-scale experiment and effects of the smoke layer

Takashi Wakamatsu*, Yuji Hasemi, Koji Kagiya, Daisuke Kamikawa

*この研究の対応する著者

研究成果: Conference contribution

8 被引用数 (Scopus)

抄録

Measurements of the heating condition of a steel beam installed beneath a ceiling and exposed to a localized fire source are made on a real-scale experiment. The data of thermal response obtained from the experiments are compared with previous small-scale experiments. The effects of the smoke layer which influences upon the heating condition of the beam are investigated through the smoke experiments setting the smoke protection soffits to the same experimental equipment. FDM-based calculation is demonstrated using the average temperature of the smoke layer for the boundary conditions to predict the thermal response of the beam. Applicability of the approximated temperature of the smoke layer is examined by comparing the numerical results of the temperature with those obtained through the experiment.

本文言語English
ホスト出版物のタイトルFire Safety Science - Proceedings of the 7th International Symposium
ページ1099-1110
ページ数12
DOI
出版ステータスPublished - 2003
外部発表はい
イベント7th International Symposium on Fire Safety Science - Worcester, MA, United States
継続期間: 2002 6月 162002 6月 21

出版物シリーズ

名前Fire Safety Science
ISSN(印刷版)1817-4299

Conference

Conference7th International Symposium on Fire Safety Science
国/地域United States
CityWorcester, MA
Period02/6/1602/6/21