High-density microcavity array for cell detection: Single-cell analysis of hematopoietic stem cells in peripheral blood mononuclear cells

Masahito Hosokawa, Atsushi Arakaki, Masayuki Takahashi, Tetsushi Mori, Haruko Takeyama, Tadashi Matsunaga*

*この研究の対応する著者

研究成果: Article査読

66 被引用数 (Scopus)

抄録

Detection and isolation of specific cell types from limited biological samples have become a major challenge in clinical diagnosis and cell biology research. Here, we report a high-density microcavity array for target cell detection in which thousands of single cells were neatly arrayed onto 10 000 microcavities with high efficiency at approximately 90% of the loaded cells. Cell-specific immunophenotypes were exclusively identified at the singlecell level by measuring fluorescence intensities of cells labeled with antibodies targeting cell surface markers, and the purity of hematopoietic stem cells (HSCs) within human peripheral blood analyzed by this system was correlated with those obtained by conventional flow cytometry. Furthermore, gene expression of the stem cell marker, CD34, was determined from HSCs by isolating single cells using a micromanipulator. This technology has proven to be an effective tool for target cell detection and subsequent cellular analytical research at the single-cell level.

本文言語English
ページ(範囲)5308-5313
ページ数6
ジャーナルAnalytical chemistry
81
13
DOI
出版ステータスPublished - 2009 7月 1
外部発表はい