T1 - Immunological Helicobacter pylori urease analyzer based on ion-sensitive field effect transistor
AU - Sekiguchi, Tetsushi
AU - Nakamura, Michihiro
AU - Kato, Mototsugu
AU - Nishikawa, Keiko
AU - Hokari, Kaku
AU - Sugiyama, Toshiro
AU - Asaka, Masahiro
PY - 2000/9/1
Y1 - 2000/9/1
N2 - Immunological Helicobacter pylori (H. pylori) urease analyzer (HPUA), based on a solid-phase tip coated with a monoclonal antibody toward H. pylori's urease and ion-sensitive field effect transistor (ISFET), was developed. In this system, H. pylori urease adsorbed on the solid-phase tip, after a 15-min immunological reaction with gastric mucus sample solution, was measured with a urease analyzer composed of a flow-through cell for urea solution equipped with the measuring and reference ISFETs. The pH change (ΔpH) of urea solution after 55 s of the enzymatic reaction inside the tip was measured by withdrawing about 1 μl of the urea solution toward the upstream of the tip, where the measuring ISFET is installed. It was confirmed that the present system could detect 0.2 mIU/ml of H. pylori urease. Clinical evaluations of the system were performed for 119 patients using urea breath test (UBT) as a gold standard, resulting in the sensitivity = 33/36 = 92% and specificity = 81/83 = 98%, respectively.
AB - Immunological Helicobacter pylori (H. pylori) urease analyzer (HPUA), based on a solid-phase tip coated with a monoclonal antibody toward H. pylori's urease and ion-sensitive field effect transistor (ISFET), was developed. In this system, H. pylori urease adsorbed on the solid-phase tip, after a 15-min immunological reaction with gastric mucus sample solution, was measured with a urease analyzer composed of a flow-through cell for urea solution equipped with the measuring and reference ISFETs. The pH change (ΔpH) of urea solution after 55 s of the enzymatic reaction inside the tip was measured by withdrawing about 1 μl of the urea solution toward the upstream of the tip, where the measuring ISFET is installed. It was confirmed that the present system could detect 0.2 mIU/ml of H. pylori urease. Clinical evaluations of the system were performed for 119 patients using urea breath test (UBT) as a gold standard, resulting in the sensitivity = 33/36 = 92% and specificity = 81/83 = 98%, respectively.
UR - http://www.scopus.com/inward/record.url?scp=0034275770&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0034275770&partnerID=8YFLogxK
U2 - 10.1016/S0925-4005(00)00522-0
DO - 10.1016/S0925-4005(00)00522-0
M3 - Article
AN - SCOPUS:0034275770
SN - 0925-4005
VL - 67
SP - 265
EP - 269
JO - Sensors and Actuators, B: Chemical
JF - Sensors and Actuators, B: Chemical
IS - 3
ER -