Improvement of thermal environment in railway station using local wind

Yuka Nakamura*, Yuki Yamada, Junta Nakano, Kiyoshi Sakamoto, Toshihiko Sato, Tadashi Iino, Shin Ichi Tanabe

*この研究の対応する著者

研究成果: Conference contribution

2 被引用数 (Scopus)

抄録

The field survey on station Y was conducted from August to October 2009. Railway tracks of station Y run along the moat from north to south and the platform is lower than the surrounding topography. According to the field survey, dominant outdoor wind from north and south was observed along the railway tracks. Air temperature of the wind was lower than the neighbouring urban area by 1°C in the evening, implying that cool winds in the north-south direction was blowing along the railway tracks. Wind along the railway tracks could not be introduced to the concourse efficiently because of the wall and closed windows in the north-south axis. On the other hand, these walls and windows shield the station from strong winds like typhoon. Adjustment of openings in the north-south axis would improve of thermal comfort and protect from strong winds in station Y.

本文言語English
ホスト出版物のタイトル12th International Conference on Indoor Air Quality and Climate 2011
ページ776-781
ページ数6
出版ステータスPublished - 2011 12月 1
イベント12th International Conference on Indoor Air Quality and Climate 2011 - Austin, TX, United States
継続期間: 2011 6月 52011 6月 10

出版物シリーズ

名前12th International Conference on Indoor Air Quality and Climate 2011
1

Conference

Conference12th International Conference on Indoor Air Quality and Climate 2011
国/地域United States
CityAustin, TX
Period11/6/511/6/10

ASJC Scopus subject areas

  • 汚染

フィンガープリント

「Improvement of thermal environment in railway station using local wind」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル