TY - JOUR
T1 - Membrane fouling and dialysate flow pattern in an internal filtration-enhancing dialyzer
AU - Yamamoto, Ken Ichiro
AU - Hiwatari, Michihito
AU - Kohori, Fukashi
AU - Sakai, Kiyotaka
AU - Fukuda, Makoto
AU - Hiyoshi, Tatsuo
PY - 2005/9
Y1 - 2005/9
N2 - For efficient removal of large molecular weight solutes by dialysis, several types of internal filtration-enhancing dialyzers (IFEDs) are commercially available. However, in a pressure-driven membrane separation process (i.e., filtration), membrane fouling caused by adhesion of plasma proteins is a severe problem. The objective of the present study is to investigate the effects of internal filtration on membrane fouling based on the membrane's pure-water permeability, diffusive permeability, and sieving coefficient. Hemodialysis experiments were performed with two different dialyzers, IFEDs and non-IFEDs. Local membrane fouling in each dialyzer was evaluated by measuring the pure-water permeability, the diffusive permeability, and the sieving coefficient of native membranes and membranes treated with bovine blood. The effects of packing ratio on dialysate flow pattern were also evaluated by measuring the time required for an ion tracer to reach electrodes placed in the dialyzers. In the IFED, membrane fouling caused by protein adhesion is increased because of enhanced internal filtration only at the early stage of dialysis, and this fouling tends to occur only near the dialysate outlet port. However, enhanced internal filtration has little effect on measured membrane transfer parameters.
AB - For efficient removal of large molecular weight solutes by dialysis, several types of internal filtration-enhancing dialyzers (IFEDs) are commercially available. However, in a pressure-driven membrane separation process (i.e., filtration), membrane fouling caused by adhesion of plasma proteins is a severe problem. The objective of the present study is to investigate the effects of internal filtration on membrane fouling based on the membrane's pure-water permeability, diffusive permeability, and sieving coefficient. Hemodialysis experiments were performed with two different dialyzers, IFEDs and non-IFEDs. Local membrane fouling in each dialyzer was evaluated by measuring the pure-water permeability, the diffusive permeability, and the sieving coefficient of native membranes and membranes treated with bovine blood. The effects of packing ratio on dialysate flow pattern were also evaluated by measuring the time required for an ion tracer to reach electrodes placed in the dialyzers. In the IFED, membrane fouling caused by protein adhesion is increased because of enhanced internal filtration only at the early stage of dialysis, and this fouling tends to occur only near the dialysate outlet port. However, enhanced internal filtration has little effect on measured membrane transfer parameters.
KW - Dialysate flow pattern
KW - Dialysis
KW - Internal filtration
KW - Internal filtration-enhancing dialyzer
KW - Membrane fouling
UR - http://www.scopus.com/inward/record.url?scp=26844518847&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=26844518847&partnerID=8YFLogxK
U2 - 10.1007/s10047-005-0303-2
DO - 10.1007/s10047-005-0303-2
M3 - Article
C2 - 16235037
AN - SCOPUS:26844518847
SN - 1434-7229
VL - 8
SP - 198
EP - 205
JO - Journal of Artificial Organs
JF - Journal of Artificial Organs
IS - 3
ER -