TY - JOUR
T1 - Microcavity array system for size-based enrichment of circulating tumor cells from the blood of patients with small-cell lung cancer
AU - Hosokawa, Masahito
AU - Yoshikawa, Takayuki
AU - Negishi, Ryo
AU - Yoshino, Tomoko
AU - Koh, Yasuhiro
AU - Kenmotsu, Hirotsugu
AU - Naito, Tateaki
AU - Takahashi, Toshiaki
AU - Yamamoto, Nobuyuki
AU - Kikuhara, Yoshihito
AU - Kanbara, Hisashige
AU - Tanaka, Tsuyoshi
AU - Yamaguchi, Ken
AU - Matsunaga, Tadashi
PY - 2013/6/18
Y1 - 2013/6/18
N2 - In this study, we present a method for efficient enrichment of small-sized circulating tumor cells (CTCs) such as those found in the blood of small-cell lung cancer (SCLC) patients using a microcavity array (MCA) system. To enrich CTCs from whole blood, a microfabricated nickel filter with a rectangular MCA (104 cavities/filter) was integrated with a miniaturized device, allowing for the isolation of tumor cells based on differences in size and deformability between tumor and blood cells. The shape and porosity of the MCA were optimized to efficiently capture small tumor cells on the microcavities under low flow resistance conditions, while allowing other blood cells to effectively pass through. Under optimized conditions, approximately 80% of SCLC (NCI-H69 and NCI-H82) cells spiked in 1 mL of whole blood were successfully recovered. In clinical samples, CTCs were detectable in 16 of 16 SCLC patients. In addition, the number of leukocytes captured on the rectangular MCA was significantly lower than that on the circular MCA (p < 0.001), suggesting that the use of the rectangular MCA diminishes a considerable number of carryover leukocytes. Therefore, our system has potential as a tool for the detection of CTCs in small cell-type tumors and detailed molecular analyses of CTCs.
AB - In this study, we present a method for efficient enrichment of small-sized circulating tumor cells (CTCs) such as those found in the blood of small-cell lung cancer (SCLC) patients using a microcavity array (MCA) system. To enrich CTCs from whole blood, a microfabricated nickel filter with a rectangular MCA (104 cavities/filter) was integrated with a miniaturized device, allowing for the isolation of tumor cells based on differences in size and deformability between tumor and blood cells. The shape and porosity of the MCA were optimized to efficiently capture small tumor cells on the microcavities under low flow resistance conditions, while allowing other blood cells to effectively pass through. Under optimized conditions, approximately 80% of SCLC (NCI-H69 and NCI-H82) cells spiked in 1 mL of whole blood were successfully recovered. In clinical samples, CTCs were detectable in 16 of 16 SCLC patients. In addition, the number of leukocytes captured on the rectangular MCA was significantly lower than that on the circular MCA (p < 0.001), suggesting that the use of the rectangular MCA diminishes a considerable number of carryover leukocytes. Therefore, our system has potential as a tool for the detection of CTCs in small cell-type tumors and detailed molecular analyses of CTCs.
UR - http://www.scopus.com/inward/record.url?scp=84879198321&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84879198321&partnerID=8YFLogxK
U2 - 10.1021/ac400167x
DO - 10.1021/ac400167x
M3 - Article
C2 - 23706033
AN - SCOPUS:84879198321
SN - 0003-2700
VL - 85
SP - 5692
EP - 5698
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 12