TY - JOUR
T1 - One-Pot Fabrication of Dendritic NiO@carbon-nitrogen Dot Electrodes for Screening Blood Glucose Level in Diabetes
AU - Akhtar, Naeem
AU - El-Safty, Sherif A.
AU - Abdelsalam, Mamdouh E.
AU - Kawarada, Hiroshi
N1 - Publisher Copyright:
© 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Copyright:
Copyright 2020 Elsevier B.V., All rights reserved.
PY - 2015/10/7
Y1 - 2015/10/7
N2 - Selective and sensitive glucose sensors with fast response for screening diabetic blood level are demanded. In this paper, the one-pot nanoarchitecture of dendritic NiO@carbon-nitrogen (C-N) dots (designated as NCD) sphere-wrapping Ni foam electrodes are reported as an effective and sensitive glucose sensor in blood samples. In this construction design, the NCD sphere electrode with excessive surface defects, large fractions of catalytic active sites, high surface area, and mobility of electron transfer through the actively surface NCD sphere can massively enhance the electrocatalytic activity for nonenzymatic glucose detection in diabetic blood. This portable sensor enables highly sensitive recognition of glucose detection (≈0.01 × 10-6m) over a wider linear range (≈0.005-12 × 10-3m) with rapid response time of a few seconds. The key result is that the engineered NCD sphere electrodes function as simple, easy-to-use electrochemical sensing assays of glucose levels in diabetic blood patients with a wide range of precision or linearity, recyclability, and excellent selectivity, even in the presence of potentially interfering organic (ascorbic acid, uric acid, dopamine, lactose, maltose, and sucrose) and inorganic (NaCl, Na2SO4, KCl, and K2SO4) species. The results demonstrate the potential for the electrochemical sensors to be used in preventing serious health problems associated with diabetes mismanagement.
AB - Selective and sensitive glucose sensors with fast response for screening diabetic blood level are demanded. In this paper, the one-pot nanoarchitecture of dendritic NiO@carbon-nitrogen (C-N) dots (designated as NCD) sphere-wrapping Ni foam electrodes are reported as an effective and sensitive glucose sensor in blood samples. In this construction design, the NCD sphere electrode with excessive surface defects, large fractions of catalytic active sites, high surface area, and mobility of electron transfer through the actively surface NCD sphere can massively enhance the electrocatalytic activity for nonenzymatic glucose detection in diabetic blood. This portable sensor enables highly sensitive recognition of glucose detection (≈0.01 × 10-6m) over a wider linear range (≈0.005-12 × 10-3m) with rapid response time of a few seconds. The key result is that the engineered NCD sphere electrodes function as simple, easy-to-use electrochemical sensing assays of glucose levels in diabetic blood patients with a wide range of precision or linearity, recyclability, and excellent selectivity, even in the presence of potentially interfering organic (ascorbic acid, uric acid, dopamine, lactose, maltose, and sucrose) and inorganic (NaCl, Na2SO4, KCl, and K2SO4) species. The results demonstrate the potential for the electrochemical sensors to be used in preventing serious health problems associated with diabetes mismanagement.
KW - Diabetic blood
KW - Electrodes, electrochemical sensors
KW - Glucose sensors
KW - NiO@carbon-nitrogen dot
UR - http://www.scopus.com/inward/record.url?scp=84943455611&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84943455611&partnerID=8YFLogxK
U2 - 10.1002/adhm.201500369
DO - 10.1002/adhm.201500369
M3 - Article
AN - SCOPUS:84943455611
SN - 2192-2640
VL - 4
SP - 2110
EP - 2119
JO - Advanced Healthcare Materials
JF - Advanced Healthcare Materials
IS - 14
ER -