Operational status of TAMA300 with the seismic attenuation system (SAS)

R. Takahashi*, K. Arai, D. Tatsumi, Mitsuhiro Fukushima, T. Yamazaki, M. K. Fujimoto, K. Agatsuma, Y. Arase, N. Nakagawa, A. Takamori, K. Tsubono, R. DeSalvo, A. Bertolini, S. Márka, V. Sannibale

*この研究の対応する著者

研究成果: Article査読

7 被引用数 (Scopus)

抄録

TAMA300 has been upgraded to improve the sensitivity at low frequencies after the last observation run in 2004. To avoid the noise caused by seismic activities, we installed a new seismic isolation system - the TAMA seismic attenuation system (SAS). Four SAS towers for the test-mass mirrors were sequentially installed from 2005 to 2006. The recycled Fabry-Perot Michelson interferometer was successfully locked with the SAS. We confirmed the reduction of both length and angular fluctuations at frequencies higher than 1 Hz owing to the SAS.

本文言語English
論文番号114036
ジャーナルClassical and Quantum Gravity
25
11
DOI
出版ステータスPublished - 2008 6月 7