Performance enhancement on gas fired water heater using titanium heat exchanger for latent heat recovery

Kyudae Hwang*, Sunggun Hyun, Kiyoshi Saito, Sunao Kawai, Katsuyuki Inagaki, Ryuji Ozawa

*この研究の対応する著者

研究成果: Article査読

抄録

The performance of natural gas (13A) fired water heater with titanium heat exchanger for latent heat recovery was evaluated. In the terms of thermal efficiency, the performance of the water heater was evaluated based on the net calorific value at maximum rated output. The thermal efficiency of gas fired water heater with latent heat recovery heat exchanger was ≈ 10% higher than that of the conventional instantaneous water heater. The overall heat conductance of the heat exchanger with staggered tube rows was more efficient than that of the inline tube rows.

本文言語English
ページ(範囲)62-67
ページ数6
ジャーナルJournal of the Japan Institute of Energy
84
1
DOI
出版ステータスPublished - 2005 1月

ASJC Scopus subject areas

  • 再生可能エネルギー、持続可能性、環境
  • 燃料技術
  • エネルギー工学および電力技術

フィンガープリント

「Performance enhancement on gas fired water heater using titanium heat exchanger for latent heat recovery」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。