Personalized HVAC system in a sustainable office building - building design concept and HVAC system performance

M. Sasaki*, T. Yanai, T. Akimoto, T. Genma, H. Amai, S. Tanabe

*この研究の対応する著者

研究成果: Conference contribution

1 被引用数 (Scopus)

抄録

HVAC load weighs a large portion of overall building energy consumption. A low storey building of 20,000m2 floor area adopted a task ambient conditioning system (TAC) in its design to reduce HVAC load while maintaining work environment. Applied in conjunction with other design techniques such as double-skin glass and structural thermal storage system, the TAC system achieved comfortable personal work-environment under reduced load.

本文言語English
ホスト出版物のタイトルHB 2006 - Healthy Buildings
ホスト出版物のサブタイトルCreating a Healthy Indoor Environment for People, Proceedings
ページ191-194
ページ数4
出版ステータスPublished - 2006 12月 1