Pressurization test on CFRP liner-less tanks at liquefied nitrogen temperature

Tetsuya Morimoto*, Takashi Ishikawa, Tomohiro Yokozeki, Yoichi Hayashi, Takayuki Shimoda, Yoshiki Morino

*この研究の対応する著者

研究成果: Article査読

6 被引用数 (Scopus)

抄録

Two liner-less CFRP concept tanks were prepared for internal pressurization tests at liquefied nitrogen (LN2) temperature. The tanks were designed in two patterns of eight-ply UD quasi-isotropic lay-up, in the shape as a cylinder of 600 mm in diameter and 1200 mm in length, covered with an aluminum flange at one end and with a CFRP hemisphere dome at the other. The maximum strain was applied as the damage onset condition so that the internal pressurization at LN2 temperature did not damage them up to 1.1 MPa. Damage onsets, such as transverse cracking and leak path formation, were monitored during the tests using helium flow detection, acoustic emission, and pressure-strain monitoring. The CFRP concept tanks showed no damage in the 1.1 mm thick cylindrical gauge section under pressurization up to 1.1 MPa at LN 2 temperature. The design was thus shown to be successful in keeping the CFRP tanks intact.

本文言語English
ページ(範囲)81-88
ページ数8
ジャーナルAdvanced Composite Materials: The Official Journal of the Japan Society of Composite Materials
13
2
DOI
出版ステータスPublished - 2004
外部発表はい

ASJC Scopus subject areas

  • セラミックおよび複合材料

フィンガープリント

「Pressurization test on CFRP liner-less tanks at liquefied nitrogen temperature」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。