TY - GEN
T1 - Pulse wave propagation and reflection in human arteries by pressure-velocity loop and impedance analysis
AU - Chang, Ye
AU - Kaneko, Shigehiko
PY - 2008/5/19
Y1 - 2008/5/19
N2 - To investigate the mechanism and the usage of the information of pulse wave propagation and reflection in human arteries are the objects of this study. In this study, an experimental apparatus simulating human circulatory system by using silicon tubes to examine the pulse wave propagation and reflection with and without branches has been developed. We examined the effect of eight parameters, such as flow rate, tube diameter, tube thickness etc., affecting waveform, PWV (Pulse Wave Velocity) and PV loop (Pressure-Velocity Loop). Numerical analyses were also carried out, and the relation between PV Loop and local impedance was discussed. Finally, the effect of eight parameters on the PWV and PV loop were clarified. It was also found that, the PV Loop includes much information on the tube characteristics, impedance, boundary condition, tube connection and reflection condition. Therefore, the PV loop method might be promising to be used in health diagnosis systems. In addition, we found that the effects of bifurcation angle on wave propagation and reflection were so little that they can be neglected in wave calculation models.
AB - To investigate the mechanism and the usage of the information of pulse wave propagation and reflection in human arteries are the objects of this study. In this study, an experimental apparatus simulating human circulatory system by using silicon tubes to examine the pulse wave propagation and reflection with and without branches has been developed. We examined the effect of eight parameters, such as flow rate, tube diameter, tube thickness etc., affecting waveform, PWV (Pulse Wave Velocity) and PV loop (Pressure-Velocity Loop). Numerical analyses were also carried out, and the relation between PV Loop and local impedance was discussed. Finally, the effect of eight parameters on the PWV and PV loop were clarified. It was also found that, the PV Loop includes much information on the tube characteristics, impedance, boundary condition, tube connection and reflection condition. Therefore, the PV loop method might be promising to be used in health diagnosis systems. In addition, we found that the effects of bifurcation angle on wave propagation and reflection were so little that they can be neglected in wave calculation models.
UR - http://www.scopus.com/inward/record.url?scp=43449103624&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=43449103624&partnerID=8YFLogxK
U2 - 10.1115/PVP2007-26175
DO - 10.1115/PVP2007-26175
M3 - Conference contribution
AN - SCOPUS:43449103624
SN - 0791842827
SN - 9780791842829
T3 - American Society of Mechanical Engineers, Pressure Vessels and Piping Division (Publication) PVP
SP - 355
EP - 363
BT - 2007 Proceedings of the ASME Pressure Vessels and Piping Conference - Fluid-Structure Interaction
T2 - 2007 ASME Pressure Vessels and Piping Conference, PVP 2007
Y2 - 22 July 2007 through 26 July 2007
ER -