TY - JOUR
T1 - Reduction in incomplete stent apposition area caused by jailed struts after single stenting at left main bifurcation lesions
T2 - micro-CT analysis using a three-dimensional elastic bifurcated coronary artery model
AU - Hikichi, Yutaka
AU - Umezu, Mitsuo
AU - Node, Koichi
AU - Iwasaki, Kiyotaka
N1 - Funding Information:
Health Science Research Grant from Ministry of Health, Labour and Welfare, Japan.
Publisher Copyright:
© 2016, The Author(s).
PY - 2017/1/1
Y1 - 2017/1/1
N2 - Stent struts protruding into ostial side branch called “jailed strut” at bifurcation lesions is a likely cause of thrombus formation. We aimed to investigate the influences of multiple kissing balloon inflation (KBI) for stent expansion, and stent platform design, respectively, on the reduction of incomplete stent apposition area (ISA area) caused by jailed struts at a side-branch ostium, using a three-dimensional elastic left main (LM) bifurcated coronary artery model. The referenced LM bifurcation angle data of 209 patients were stratified by tertiles focusing on the angle between the LM trunk (LMT) and left anterior descending artery (LAD). A bifurcation model was fabricated with angles of 129°, 122.2°, and 76.4° for LMT–LAD, LMT–left circumflex (LCx), and LAD–LCx, respectively, and with diameters of 5, 3.75, and 3.5 mm for LMT, LAD, and LCx, respectively; these diameters fulfill Murray’s law. A 75 % stenosis was included along the LMT. One-time and three-time KBIs were conducted using two-link Nobori and three-link Xience Xpedition (n = 6 each). The ISA area was quantified using micro-CT. Three-time KBI was effective in reducing the ISA area compared with one-time KBI for both the Nobori (p = 0.05) and Xience Xpedition (p = 0.07). The ISA area was smaller in the Nobori than in the Xience Xpedition, both in one-time and three-time KBI (one-time KBI: p = 0.003; three-time KBI: p = 0.001). Our findings of this study on reducing the ISA area by focusing on an interventional technique and stent design may help to improve coronary bifurcation intervention for a possibly better long-term clinical outcome.
AB - Stent struts protruding into ostial side branch called “jailed strut” at bifurcation lesions is a likely cause of thrombus formation. We aimed to investigate the influences of multiple kissing balloon inflation (KBI) for stent expansion, and stent platform design, respectively, on the reduction of incomplete stent apposition area (ISA area) caused by jailed struts at a side-branch ostium, using a three-dimensional elastic left main (LM) bifurcated coronary artery model. The referenced LM bifurcation angle data of 209 patients were stratified by tertiles focusing on the angle between the LM trunk (LMT) and left anterior descending artery (LAD). A bifurcation model was fabricated with angles of 129°, 122.2°, and 76.4° for LMT–LAD, LMT–left circumflex (LCx), and LAD–LCx, respectively, and with diameters of 5, 3.75, and 3.5 mm for LMT, LAD, and LCx, respectively; these diameters fulfill Murray’s law. A 75 % stenosis was included along the LMT. One-time and three-time KBIs were conducted using two-link Nobori and three-link Xience Xpedition (n = 6 each). The ISA area was quantified using micro-CT. Three-time KBI was effective in reducing the ISA area compared with one-time KBI for both the Nobori (p = 0.05) and Xience Xpedition (p = 0.07). The ISA area was smaller in the Nobori than in the Xience Xpedition, both in one-time and three-time KBI (one-time KBI: p = 0.003; three-time KBI: p = 0.001). Our findings of this study on reducing the ISA area by focusing on an interventional technique and stent design may help to improve coronary bifurcation intervention for a possibly better long-term clinical outcome.
KW - Incomplete stent apposition
KW - Jailed strut
KW - Left main bifurcation
KW - Stent design
KW - Stent expansion method
UR - http://www.scopus.com/inward/record.url?scp=85008319127&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85008319127&partnerID=8YFLogxK
U2 - 10.1007/s12928-016-0380-6
DO - 10.1007/s12928-016-0380-6
M3 - Article
C2 - 26968169
AN - SCOPUS:85008319127
SN - 1868-4300
VL - 32
SP - 12
EP - 17
JO - Cardiovascular Intervention and Therapeutics
JF - Cardiovascular Intervention and Therapeutics
IS - 1
ER -