Removal of estrogens by electrochemical oxidation process

Vo Huu Cong, Sota Iwaya, Yutaka Sakakibara*

*この研究の対応する著者

研究成果: Article査読

16 被引用数 (Scopus)

抄録

Treatments of estrogens such as Estrone (E1), Estradiol (E2) and Ethinylestradiol (EE2) were conducted using an electrolytic reactor equipped with multi-packed granular glassy carbon electrodes. Experimental results showed that E1, E2 and EE2 were oxidized in the range of 0.45-0.85 V and were removed through electro-polymerization. Observed data from continuous experiments were in good agreement with calculated results by a mathematical model constructed based on mass transfer limitation. In continuous treatment of trace estrogens (1 μg/L), 98% of E1, E2 and EE2 were stably removed. At high loading rate (100 μg/L), removal efficiency of E1 was kept around 74%-88% for 21 days, but removal efficiency reduced due to passivation of electrodes. However, removal efficiency was recovered after electrochemical regeneration of electrodes in presence of ozone. Electric energy consumption was observed in the range of 1-2 Wh/m3. From these results, we concluded that the present electrochemical process would be an alternative removal of estrogens.

本文言語English
ページ(範囲)1355-1360
ページ数6
ジャーナルJournal of Environmental Sciences (China)
26
6
DOI
出版ステータスPublished - 2014 6月 1

ASJC Scopus subject areas

  • 環境工学
  • 環境化学
  • 環境科学(全般)