TY - JOUR
T1 - Response control of seismic isolated buildings using developed passive-switching oil damper with Bi-flow mechanism
AU - Maseki, Ryota
AU - Nagashima, Ichiro
AU - Nii, Aiko
AU - Kimura, Yuichi
AU - Nishitani, Akira
PY - 2015
Y1 - 2015
N2 - The authors have developed a passive-switching oil damper for seismic isolated structures that can control the displacement response of isolation layer within design limit under extreme earthquake events while maintains the acceleration response of superstructure in acceptable level in major and moderate earthquake events. The fundamental performance characteristics of the damper are experimentally tested. Then, the earthquake responses of a seismically isolated building model with the damper installed are simulated. The simulated results show that, with the aid of the damper, the building model would reduce the acceleration responses both to major and moderate quakes, and the isolation layer would not exhibit such displacement responses to extremely large quakes as to exceed the clearance gap. In addition, the rotation resulting from unbalanced switching of the dampers installed in opposite ends of the building is assessed. The rotational responses are confrrrned to be in small level.
AB - The authors have developed a passive-switching oil damper for seismic isolated structures that can control the displacement response of isolation layer within design limit under extreme earthquake events while maintains the acceleration response of superstructure in acceptable level in major and moderate earthquake events. The fundamental performance characteristics of the damper are experimentally tested. Then, the earthquake responses of a seismically isolated building model with the damper installed are simulated. The simulated results show that, with the aid of the damper, the building model would reduce the acceleration responses both to major and moderate quakes, and the isolation layer would not exhibit such displacement responses to extremely large quakes as to exceed the clearance gap. In addition, the rotation resulting from unbalanced switching of the dampers installed in opposite ends of the building is assessed. The rotational responses are confrrrned to be in small level.
KW - Isolation layer displacement control
KW - Passive-switching oil damper
KW - Simple control
KW - Variable base isolation system
UR - http://www.scopus.com/inward/record.url?scp=84940094848&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84940094848&partnerID=8YFLogxK
U2 - 10.3130/aijs.80.1023
DO - 10.3130/aijs.80.1023
M3 - Article
AN - SCOPUS:84940094848
SN - 1340-4202
VL - 80
SP - 1023
EP - 1032
JO - Journal of Structural and Construction Engineering
JF - Journal of Structural and Construction Engineering
IS - 713
ER -