TY - JOUR
T1 - Seasonal performance evaluation of CO2 open refrigerated display cabinets
AU - Redo, Mark Anthony
AU - Ohno, Keisuke
AU - Giannetti, Niccolo
AU - Yamaguchi, Seiichi
AU - Saito, Kiyoshi
N1 - Funding Information:
This research is based on the results of the project ?Method for estimating the GHG reduction potential of air conditioners and refrigeration equipment using non-fluorinated gases? (FY 2015-2017), conducted by the Ministry of the Environment, Government of Japan, in collaboration with the Mitsubishi Research Institute.
Publisher Copyright:
© 2019 Elsevier Ltd
PY - 2019/12/25
Y1 - 2019/12/25
N2 - An increasing number of supermarkets and convenience stores has led to a proportionally higher demand for open refrigerated display cabinets (ORDCs). Ease of access to refrigerated products is the main advantage of ORDCs; however, they also exhibit high cumulative energy consumption as well as direct and indirect CO2 emissions. This work aims to formulate, establish, and apply a seasonal performance evaluation method for ORDCs and “walk-in” type refrigerated device driven by CO2 chillers. First, a thermodynamic modeling approach is used and fitted to experimental data. The relative error between the predicted and actual heat load is within ±10%, whereas it is within ±20% for the normalized compressor electric input. Then, an evaluation tool is constructed using the seasonal energy consumption of ORDCs commonly used in Japan and driven by a transcritical CO2-compression chiller within Japanese climatic conditions. This tool can be used to predict the annual energy demand for given ambient conditions as well as the reduced environmental impact of multiple combinations of refrigerated display cabinets compared to conventional HFC/HCFC-based systems. According to the annual temperature distribution in chosen regions, the annual thermal load, annual electricity consumption, and annual coefficient of performance are calculated and analyzed. Simulation results quantitatively evaluate the beneficial effect of Te as being translated to a better COP, and lower energy consumption and CO2 emissions. Considering the geographic location of the store, the quantitative results show how a hotter climatic condition leads to higher energy consumption and CO2 emissions, and lower COP. The proposed evaluation method is generally applicable to any regional setting and any chiller-ORDC combination.
AB - An increasing number of supermarkets and convenience stores has led to a proportionally higher demand for open refrigerated display cabinets (ORDCs). Ease of access to refrigerated products is the main advantage of ORDCs; however, they also exhibit high cumulative energy consumption as well as direct and indirect CO2 emissions. This work aims to formulate, establish, and apply a seasonal performance evaluation method for ORDCs and “walk-in” type refrigerated device driven by CO2 chillers. First, a thermodynamic modeling approach is used and fitted to experimental data. The relative error between the predicted and actual heat load is within ±10%, whereas it is within ±20% for the normalized compressor electric input. Then, an evaluation tool is constructed using the seasonal energy consumption of ORDCs commonly used in Japan and driven by a transcritical CO2-compression chiller within Japanese climatic conditions. This tool can be used to predict the annual energy demand for given ambient conditions as well as the reduced environmental impact of multiple combinations of refrigerated display cabinets compared to conventional HFC/HCFC-based systems. According to the annual temperature distribution in chosen regions, the annual thermal load, annual electricity consumption, and annual coefficient of performance are calculated and analyzed. Simulation results quantitatively evaluate the beneficial effect of Te as being translated to a better COP, and lower energy consumption and CO2 emissions. Considering the geographic location of the store, the quantitative results show how a hotter climatic condition leads to higher energy consumption and CO2 emissions, and lower COP. The proposed evaluation method is generally applicable to any regional setting and any chiller-ORDC combination.
KW - Annual energy consumption
KW - CO emission
KW - CO refrigerant
KW - Open refrigerated display cabinet
KW - Seasonal evaluation method
UR - http://www.scopus.com/inward/record.url?scp=85072213939&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85072213939&partnerID=8YFLogxK
U2 - 10.1016/j.applthermaleng.2019.114354
DO - 10.1016/j.applthermaleng.2019.114354
M3 - Article
AN - SCOPUS:85072213939
SN - 1359-4311
VL - 163
JO - Journal of Heat Recovery Systems
JF - Journal of Heat Recovery Systems
M1 - 114354
ER -