Simulation of droplet generation in micro flow using MPS method

Takahiro Harada*, Yukihito Suzuki, Seiichi Koshizuka, Takahiro Arakawa, Shuichi Shoji

*この研究の対応する著者

研究成果: Article査読

18 被引用数 (Scopus)

抄録

Micro droplet generation is one of the basic functions in a micro total analysis system (micro TAS). Micro TAS has a lot of advantages and thus has wide range of applications in these days. In this study, a numerical calculation code for micro multi-phase flow is developed using Moving Particle Semi-implicit (MPS) method. Since surface tension is extremely strong and dominant in micro multi-phase flow, a time step is divided to sub-time steps for the surface tension term. This sub-time step algorithm enables us to calculate micro multi-phase flow efficiently with keeping numerical stability. Micro droplet generation in a micro channel is analyzed by the present code in two dimensions. The calculated droplet size, pitch and production rate show good agreement with those of the experiment.

本文言語English
ページ(範囲)731-736
ページ数6
ジャーナルJSME International Journal, Series B: Fluids and Thermal Engineering
49
3
DOI
出版ステータスPublished - 2006
外部発表はい