抄録
The possibility to apply the active hub-flap control method, which is a proven rotating stall control method for a single-stage compressor, to a 3-stage axial compressor is experimentally discussed, where complex rotating stall inception processes are observed. The research compressor is a 3-stage one and could change the stagger angle settings for rotor blades and stator vanes. Sixteen rotor blade/stator vane configuration patterns were tested by changing stagger angle for the stator vanes. By measurement of surface-pressure fluctuation, stall inception processes are investigated and the measured pressure fluctuation data is used as a predictive signal for rotating stall. The experimental results show that the stall detection system applied to active hub-flap control in a single-stage compressor could be usefully applied to that in a 3-stage compressor with a more complex stall inception process.
本文言語 | English |
---|---|
ページ(範囲) | 324-330 |
ページ数 | 7 |
ジャーナル | Journal of Thermal Science |
巻 | 17 |
号 | 4 |
DOI | |
出版ステータス | Published - 2008 12月 |
ASJC Scopus subject areas
- 凝縮系物理学