Study on condensation heat transfer under high-temperature, high-pressure conditions

H. Yuasa*, N. Abe, H. Ono, K. Shirakawa, Shinichi Morooka

*この研究の対応する著者

研究成果: Conference contribution

抄録

Knowing the predietcd overpressure rate under antieipated operational oeeurrcnecs (AOOs) is very important when evaluating the integrity of a BWR reactor pressure vessel. One of the factors that influence the overpressure rate is the wall condensing performance. Many condensing studies have been done under low-pressure conditions without vapor flow, but few condensing test results under BWR conditions have been reported. Therefore, the purposes of this study were to extend the vapor condensing data base for high-pressure, high-temperature conditions, to improve the heat transfer correlation and to evaluate the condensing effect on the overpressure rate. Condensation heat transfer tests have been performed with the pressure range from 0.5 to 8 MPa under upward and downward vapor flow. The test section consisted of a condensing tube and a water-cooling jacket. The condensing tube was a circular tube. The test results showed that the condensation heat transfer coefficient increased with the velocity of vapor flow due to enhancement of heat transfer caused by turbulence of the liquid film. We obtained a new correlation for condensation heat transfer that considered vapor shear force and condensate film Reynolds number. This new correlation agreed well with experimental data over a wide range of pressure. New correlation was incorporated into TRACG02modTI code. When the condensation heat transfer tests were analyzed using this modified TRACG02modTl code, the calculated condensation heat transfer coefficients were found to be in considerable agreement with the measured data. Furthermore, when ihe main steam isolation valve AOO (safety relief valve capacity design) of the BWR plant was evaluated by this modified TRACG02modTI code, we found that the vapor condensation effect appeared under relatively high-pressure conditions and the pressure with improved condensation model was lower than that without vapor condensation. In summary, the condensation heat transfer model of TRACG02modTI code has been improved based on high-pressure, high-temperature condensation test data with vapor flow. The vapor condensation effect was found to be strong, especially in the pressure increase AOO of the actual plant.

本文言語English
ホスト出版物のタイトルInternational Conference on Nuclear Engineering, Proceedings, ICONE
ページ75-80
ページ数6
3
DOI
出版ステータスPublished - 2008
外部発表はい
イベント16th International Conference on Nuclear Engineering, ICONE16 2008 - Orlando, FL
継続期間: 2008 5月 112008 5月 15

Other

Other16th International Conference on Nuclear Engineering, ICONE16 2008
CityOrlando, FL
Period08/5/1108/5/15

ASJC Scopus subject areas

  • 原子力エネルギーおよび原子力工学

フィンガープリント

「Study on condensation heat transfer under high-temperature, high-pressure conditions」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル