TY - JOUR
T1 - Study on the effect of the difference of absorption cycles on the characteristics of double-effect absorption refrigerator
AU - Saito, Kiyoshi
AU - Igarashi, Hiroteru
AU - Kawai, Sunao
PY - 1996
Y1 - 1996
N2 - As a result of the problem of ecological destruction due to the use of CFC, HCFC, HFC, the use of absorption refrigerators has been attracting greater attention, and improvement in the quality of these refrigerators is in demand. There are three types of solution flow for the double-effect absorption refrigerator. They are series flow, parallel flow, and the reverse flow; each has its own characteristics. As yet little research into the differences in performance according to solution flow type has been conducted. Therefore, definitive comparison of the performances has not been made yet. This study aims to clarify the differences in the double-effect absorption refrigerator which result from the solution flow type. The differences in characteristics of double-effect absorption refrigerators driven by gas depending on the three types of solution flow were developed and compared using a simulation model. As a result we were able to identify the merit of each flow type.
AB - As a result of the problem of ecological destruction due to the use of CFC, HCFC, HFC, the use of absorption refrigerators has been attracting greater attention, and improvement in the quality of these refrigerators is in demand. There are three types of solution flow for the double-effect absorption refrigerator. They are series flow, parallel flow, and the reverse flow; each has its own characteristics. As yet little research into the differences in performance according to solution flow type has been conducted. Therefore, definitive comparison of the performances has not been made yet. This study aims to clarify the differences in the double-effect absorption refrigerator which result from the solution flow type. The differences in characteristics of double-effect absorption refrigerators driven by gas depending on the three types of solution flow were developed and compared using a simulation model. As a result we were able to identify the merit of each flow type.
UR - http://www.scopus.com/inward/record.url?scp=0030103198&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0030103198&partnerID=8YFLogxK
U2 - 10.1299/kikaib.62.1193
DO - 10.1299/kikaib.62.1193
M3 - Article
AN - SCOPUS:0030103198
SN - 0387-5016
VL - 62
SP - 1193
EP - 1197
JO - Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B
JF - Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B
IS - 595
ER -