TY - JOUR
T1 - Study on the start-up characteristics of a double-effect absorption refrigerator driven by waste steam
AU - Saito, Kiyoshi
AU - Nishiyama, Noriyuki
AU - Kawai, Sunao
PY - 1997
Y1 - 1997
N2 - Absorption refrigerator can be driven by waste heat. In particular, the double-effect type absorption refrigerator, which is highly efficient, is drawing a great deal of attention as a waste heat recovery system. This research refers to the double-effect absorption refrigerator driven by steam, assuming waste heat from the fuel cells is applied. In the start up of the double-effect absorption refrigerator, the solution temperature is almost equal to the temperature of the air. Due to the large temperature difference between the solution and the heat sources, the solution is over heated. In the worst case, it will be crystallized. Additionally, some solution is circulated due to the existence of a pressure difference between the heat exchangers. If the solution pump is started before an adequate pressure difference is obtained, the absorption refrigerator cannot be started normally. To investigate these problems, the simulation model is constructed. An experiment is conducted to investigate the performance of this model. As a result, the validity of this model is confirmed and the detailed start-up characteristics are clarified.
AB - Absorption refrigerator can be driven by waste heat. In particular, the double-effect type absorption refrigerator, which is highly efficient, is drawing a great deal of attention as a waste heat recovery system. This research refers to the double-effect absorption refrigerator driven by steam, assuming waste heat from the fuel cells is applied. In the start up of the double-effect absorption refrigerator, the solution temperature is almost equal to the temperature of the air. Due to the large temperature difference between the solution and the heat sources, the solution is over heated. In the worst case, it will be crystallized. Additionally, some solution is circulated due to the existence of a pressure difference between the heat exchangers. If the solution pump is started before an adequate pressure difference is obtained, the absorption refrigerator cannot be started normally. To investigate these problems, the simulation model is constructed. An experiment is conducted to investigate the performance of this model. As a result, the validity of this model is confirmed and the detailed start-up characteristics are clarified.
UR - http://www.scopus.com/inward/record.url?scp=0031276049&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0031276049&partnerID=8YFLogxK
U2 - 10.1299/kikaib.63.3691
DO - 10.1299/kikaib.63.3691
M3 - Article
AN - SCOPUS:0031276049
SN - 0387-5016
VL - 63
SP - 3691
EP - 3699
JO - Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B
JF - Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B
IS - 615
ER -