Subjective ratings of heavy-weight floor impact sounds in wood frame construction

Jongkwan Ryu, Hiroshi Sato*, Kenji Kurakata, Atsuo Hiramitsu, Manabu Tanaka, Tomohito Hirota

*この研究の対応する著者

研究成果: Article査読

7 被引用数 (Scopus)

抄録

The subjective ratings of heavy-weight floor impact sounds in wood frame construction were examined. Heavy-weight floor impact sounds were recorded in a mock-up building, which had four floors and two rooms each floor. The different insulation treatments were installed in the floors of each room and walls separating rooms. The stimuli consisted of 48 sounds (4 types × 2 receiver positions × 6 rooms) recorded in the mock-up building, which had 49-78 dB in the single number rating index (Lii,Fmax,r). Low pass filter with cutoff frequency 1.5 kHz was applied to remove electrical noise components in higher frequency range. The pink noise was produced from 8 loud speakers at every each 45 degree at the 1.75 m from subject and at the height of subject's ear positions. The results showed that sound insulations in higher frequency octave bands are more effective to decrease annoyance than those in lower frequency octave bands for the heavy-weight impact sound.

本文言語English
ページ(範囲)371-375
ページ数5
ジャーナルAcoustical Science and Technology
31
5
DOI
出版ステータスPublished - 2010
外部発表はい

ASJC Scopus subject areas

  • 音響学および超音波学

フィンガープリント

「Subjective ratings of heavy-weight floor impact sounds in wood frame construction」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル