抄録
Measurements of alpha-particle-induced charge collection efficiency (CCE) together with simulation analysis have been carried out for several types of substrates: a double well, a p-well in a p- epitaxial layer grown on p+ substrate (epi-substrate) and a p-well with a buried defect layer. As a result, the following have been clarified. CCE for the double well is low because the bottom n-layer acts as an effective electron absorber. CCE for the p-well in the epi-substrate increases with increase in the thickness of the epilayer because the potential difference between the heavily doped substrate and the lightly doped epilayer forms a barrier which prevents electrons from traveling into the substrate. Even for the p-well in a thin epilayer, CCE is comparable to that for the p-well in the conventional p- substrate. CCE for the p-well with a buried defect layer formed by high-energy and high-dosage ion implantation is as low as CCE for the double well because the carrier lifetime is short in the buried layer due to lattice defects.
本文言語 | English |
---|---|
ページ(範囲) | 869-873 |
ページ数 | 5 |
ジャーナル | Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers |
巻 | 35 |
号 | 2 SUPPL. B |
DOI | |
出版ステータス | Published - 1996 2月 |
外部発表 | はい |
ASJC Scopus subject areas
- 工学(全般)
- 物理学および天文学(全般)