Thermal comfort zone of SEMI-outdoor public spaces

Junta Nakano*, Shin Ichi Tanabe

*この研究の対応する著者

研究成果: Paper査読

抄録

Adaptive comfort zone and acceptability zone were determined for semi-outdoor public spaces based on seasonal field surveys. Analysis was based on 2284 valid questionnaire responses of actual visitors and corresponding sets of environmental variables measured around each respondent. Thermal preference vote was paired with overall discomfort and unacceptability vote. Occupants tended to feel greater degree of dissatisfaction on warmer SET in HVAC spaces and on cooler SET in non-HVAC spaces. Comfort zone was found to be 18.5 - 30 °C SET in HVAC spaces and 14.5 - 32 °C SET in non-HVAC spaces. Occupants were thermally comfortable in twice the wider range in HVAC spaces and thrice the wider range in non-HVAC spaces than the PPD prediction. Derivation of SET for each occupants accounts for behavioural adaptation, and the difference observed for HVAC spaces and Non-HVAC spaces resulted from the difference in psychological adaptation.

本文言語English
ページ314-319
ページ数6
出版ステータスPublished - 2014 1月 1
イベント13th International Conference on Indoor Air Quality and Climate, Indoor Air 2014 - Hong Kong, Hong Kong
継続期間: 2014 7月 72014 7月 12

Conference

Conference13th International Conference on Indoor Air Quality and Climate, Indoor Air 2014
国/地域Hong Kong
CityHong Kong
Period14/7/714/7/12

ASJC Scopus subject areas

  • 汚染
  • 建築および建設
  • 健康、毒物学および変異誘発
  • コンピュータ サイエンスの応用

フィンガープリント

「Thermal comfort zone of SEMI-outdoor public spaces」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル