TY - JOUR
T1 - TiN electrode reactor for disinfection of drinking water
AU - Matsunaga, Tadashi
AU - Okochi, Mina
AU - Takahashi, Minako
AU - Nakayama, Tsuruo
AU - Wake, Hitoshi
AU - Nakamura, Noriyuki
PY - 2000/8/15
Y1 - 2000/8/15
N2 - Titanium nitride (TiN) is a biocompatible material and has very low electrical resistance. Electrochemical control of pathogenic microbes derived from a drinking water distribution system was investigated using a TiN electrode. When a potential of 1.2 V vs saturated calomel electrode (SCE) was applied, the survival ratio of microorganisms decreased to below 40%. Changes in pH were not observed at 1.2 V vs SCE. Also, by applying -0.6 V vs SCE for 30 min, 69% of cells on the electrode surface were detached by the electrostatic repulsion. Therefore, an electrochemical disinfection reactor using a TiN mesh as the working electrode and the counter electrode was constructed. The drinking water containing mean viable cell concentration of 73 cells/ml was continuously passed through the reactor at a flow rate of 15 ml/min. The viable cell concentration in treated water decreased to below 5 cells/ml. When no potential was applied, cell concentration in treated water gradually increased after 200 h of reactor operation. In contrast, when alternating potentials of 1.2 and -0.6 V vs silver/silver chloride (Ag/AgCl) were applied to the TiN mesh working electrode, the viable cell concentration remained below 100 cells/ml during a 440 h operation. The reactor for drinking water disinfection incorporated with the TiN mesh electrode worked effectively by applying alternating potentials of 1.2 and -0.6 V vs Ag/AgCl. (C) 2000 Elsevier Science Ltd.
AB - Titanium nitride (TiN) is a biocompatible material and has very low electrical resistance. Electrochemical control of pathogenic microbes derived from a drinking water distribution system was investigated using a TiN electrode. When a potential of 1.2 V vs saturated calomel electrode (SCE) was applied, the survival ratio of microorganisms decreased to below 40%. Changes in pH were not observed at 1.2 V vs SCE. Also, by applying -0.6 V vs SCE for 30 min, 69% of cells on the electrode surface were detached by the electrostatic repulsion. Therefore, an electrochemical disinfection reactor using a TiN mesh as the working electrode and the counter electrode was constructed. The drinking water containing mean viable cell concentration of 73 cells/ml was continuously passed through the reactor at a flow rate of 15 ml/min. The viable cell concentration in treated water decreased to below 5 cells/ml. When no potential was applied, cell concentration in treated water gradually increased after 200 h of reactor operation. In contrast, when alternating potentials of 1.2 and -0.6 V vs silver/silver chloride (Ag/AgCl) were applied to the TiN mesh working electrode, the viable cell concentration remained below 100 cells/ml during a 440 h operation. The reactor for drinking water disinfection incorporated with the TiN mesh electrode worked effectively by applying alternating potentials of 1.2 and -0.6 V vs Ag/AgCl. (C) 2000 Elsevier Science Ltd.
KW - Biocompatible material
KW - Disinfection reactor
KW - Drinking water
KW - Titanium nitride
UR - http://www.scopus.com/inward/record.url?scp=0034664176&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0034664176&partnerID=8YFLogxK
U2 - 10.1016/S0043-1354(00)00066-X
DO - 10.1016/S0043-1354(00)00066-X
M3 - Article
AN - SCOPUS:0034664176
SN - 0043-1354
VL - 34
SP - 3117
EP - 3122
JO - Water Research
JF - Water Research
IS - 12
ER -