TY - JOUR
T1 - Trajectory Planning for Abdominal Fine Needle Insertion Based on Insertion Angles
AU - Tsumura, Ryosuke
AU - Iwata, Hiroyasu
N1 - Publisher Copyright:
© 2016 IEEE.
PY - 2017/4
Y1 - 2017/4
N2 - Fine needles can easily be deflected, making accurate needle insertion into a tumor difficult. In particular, it is difficult to insert the needle into a tumor in the lower abdomen because the needle has to pass through various tissues. Therefore, for lower abdominal needle insertion, we intend to develop a planning method for the optimal insertion path to minimize the deflection based on computed tomography images. In this letter, we analyze the deflection while performing needle insertion with axial rotation under conditions of various insertion angles into individual tissues composing the lower abdomen (pork loin and porcine small bowel) and develop a basic planning procedure to determine the optimal insertion path based on the analysis. From the results, we confirmed that the insertion angle should be minimized as much as possible. We then develop a planning method based on insertion angles into individual tissues the needle needs to pass through. We assumed that it is possible to determine the optimal insertion path by providing a weighting factor to the effect of the insertion angle depending on the depth of insertion, considering that the effect of the insertion angle on deflection in deep places of the body is smaller than the effect around the body surface. To verify the concept of the proposed planning procedure, we perform experiments with a simple model composed of two tissues. From the results, we show that the optimal insertion path can be planned by setting the optimal ratio of individual weighting factors.
AB - Fine needles can easily be deflected, making accurate needle insertion into a tumor difficult. In particular, it is difficult to insert the needle into a tumor in the lower abdomen because the needle has to pass through various tissues. Therefore, for lower abdominal needle insertion, we intend to develop a planning method for the optimal insertion path to minimize the deflection based on computed tomography images. In this letter, we analyze the deflection while performing needle insertion with axial rotation under conditions of various insertion angles into individual tissues composing the lower abdomen (pork loin and porcine small bowel) and develop a basic planning procedure to determine the optimal insertion path based on the analysis. From the results, we confirmed that the insertion angle should be minimized as much as possible. We then develop a planning method based on insertion angles into individual tissues the needle needs to pass through. We assumed that it is possible to determine the optimal insertion path by providing a weighting factor to the effect of the insertion angle depending on the depth of insertion, considering that the effect of the insertion angle on deflection in deep places of the body is smaller than the effect around the body surface. To verify the concept of the proposed planning procedure, we perform experiments with a simple model composed of two tissues. From the results, we show that the optimal insertion path can be planned by setting the optimal ratio of individual weighting factors.
KW - Needle insertion
KW - Path planning
UR - http://www.scopus.com/inward/record.url?scp=85063308551&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85063308551&partnerID=8YFLogxK
U2 - 10.1109/LRA.2017.2670145
DO - 10.1109/LRA.2017.2670145
M3 - Article
AN - SCOPUS:85063308551
SN - 2377-3766
VL - 2
SP - 1226
EP - 1231
JO - IEEE Robotics and Automation Letters
JF - IEEE Robotics and Automation Letters
IS - 2
M1 - 7857784
ER -