Uniform DC electric field exposure systems for mice and cats

Tetsuo Kobayashi*, Koichi Shimizu, Goro Matsumoto, Fumihiko Nishiyama, Hiroshi Nakamura, Shunro Ohta, Masamichi Kato

*この研究の対応する著者

研究成果: Article査読

3 被引用数 (Scopus)

抄録

In most previous 50/60‐Hz experiments, subjects were placed in a dielectric cage and the electric field was applied from outside the cage. Although the field outside the cage was kept uniform in space and constant in time, the field inside the cage undergoes undesirable temporal and spatial variations. We have designed an electric‐field exposure system that overcomes these problems by having a metal cage constitute a part of the field generating electrodes. The uniformity along the diameter of the cages for mice and cats are more than 84.2% and 74.3%, respectively.

本文言語English
ページ(範囲)303-314
ページ数12
ジャーナルBioelectromagnetics
4
4
DOI
出版ステータスPublished - 1983
外部発表はい