TY - JOUR
T1 - Use of YAP(Ce) in the development of high spatial resolution radiation imaging detectors
AU - Yamamoto, Seiichi
AU - Kamada, Kei
AU - Yoshikawa, Akira
N1 - Funding Information:
This study was partly supported by JSPS KAKENHI Grant Number JP18956830 .
Publisher Copyright:
© 2018 Elsevier Ltd
PY - 2018/12
Y1 - 2018/12
N2 - A scintillator with a high light output is considered to be required for the development of high spatial resolution radiation imaging detectors. In contrast to this scientific consensus, we found that high spatial resolution images can be obtained using a medium light output scintillator comprising cerium-doped yttrium aluminum perovskite, YA1O3 (YAP(Ce)). We evaluated the performance of a radiation imaging detector comprising a 0.5 mm thick YAP(Ce) plate, which was optically coupled to a 25.4 mm (1-inch) square position-sensitive photomultiplier. The Anger principle was used to calculate the radiation positions. The spatial resolution and energy resolution for the imaging detector with 5.5 MeV alpha particles were 0.25 mm full width at half-maximum (FWHM) and 7.4% FWHM, respectively. The spatial resolutions for 60 keV gamma photons and ∼32 keV X-rays were ∼0.6 mm FWHM and ∼0.8 mm FWHM, respectively. The spatial resolution of the detector when imaging beta particles at a maximum energy of 254 keV was less than 0.6 mm FWHM. We conclude that YAP(Ce) is a promising scintillator for developing high spatial resolution and high energy resolution radiation detectors for imaging alpha particles, beta particles, and gamma photons.
AB - A scintillator with a high light output is considered to be required for the development of high spatial resolution radiation imaging detectors. In contrast to this scientific consensus, we found that high spatial resolution images can be obtained using a medium light output scintillator comprising cerium-doped yttrium aluminum perovskite, YA1O3 (YAP(Ce)). We evaluated the performance of a radiation imaging detector comprising a 0.5 mm thick YAP(Ce) plate, which was optically coupled to a 25.4 mm (1-inch) square position-sensitive photomultiplier. The Anger principle was used to calculate the radiation positions. The spatial resolution and energy resolution for the imaging detector with 5.5 MeV alpha particles were 0.25 mm full width at half-maximum (FWHM) and 7.4% FWHM, respectively. The spatial resolutions for 60 keV gamma photons and ∼32 keV X-rays were ∼0.6 mm FWHM and ∼0.8 mm FWHM, respectively. The spatial resolution of the detector when imaging beta particles at a maximum energy of 254 keV was less than 0.6 mm FWHM. We conclude that YAP(Ce) is a promising scintillator for developing high spatial resolution and high energy resolution radiation detectors for imaging alpha particles, beta particles, and gamma photons.
KW - Energy resolution
KW - Position-sensitive photomultiplier
KW - Spatial resolution
KW - YAP(Ce)
UR - http://www.scopus.com/inward/record.url?scp=85056642000&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85056642000&partnerID=8YFLogxK
U2 - 10.1016/j.radmeas.2018.11.001
DO - 10.1016/j.radmeas.2018.11.001
M3 - Article
AN - SCOPUS:85056642000
SN - 1350-4487
VL - 119
SP - 184
EP - 191
JO - Radiation Measurements
JF - Radiation Measurements
ER -