TY - GEN
T1 - User-friendly walking assistance device able to walk on stairs safely
AU - Zhang, Y.
AU - Tanaka, E.
AU - Lee, H.
AU - Saegusa, S.
AU - Yuge, L.
N1 - Publisher Copyright:
© 2017 IEEE.
PY - 2017/8/21
Y1 - 2017/8/21
N2 - A novel control method for the walking assistance device using predefined walking trajectory used to walk for the elderly or the patients with weak leg muscle on stairs from plain more safely and naturally is proposed in this paper. Two control method, torque control and impedance control, used per their usage purpose are introduced, and the later one is focused in this paper. To make sure the use of safety, two situations, putting swing leg in front of stair too close or too far, while a user wearing assistance climbing up on the stairs through even ground is considered. If the user faces these situations walking with the apparatus using impedance control, falling or collision between apparatus and stair are happened more easily than level walking because of lots of environment facts need to be considered like the distance between user and stairs. One of the most important environment facts is recognizing of the stairs, therefore, to prevent the user from the danger in each situation, ultrasonic sensor is used as a safety system to keep space, and we called safety distance, between foot part of walking device and stair. The value of safety distance is not only defined as a switch to change the walking trajectory between the plain mode and the stair mode but also used to decide the ideal stride of trajectory while walking to stairs from even ground. Finally, the result of walking experiment shows that the safety walking experience by wearing our walking assistance device can be achieved.
AB - A novel control method for the walking assistance device using predefined walking trajectory used to walk for the elderly or the patients with weak leg muscle on stairs from plain more safely and naturally is proposed in this paper. Two control method, torque control and impedance control, used per their usage purpose are introduced, and the later one is focused in this paper. To make sure the use of safety, two situations, putting swing leg in front of stair too close or too far, while a user wearing assistance climbing up on the stairs through even ground is considered. If the user faces these situations walking with the apparatus using impedance control, falling or collision between apparatus and stair are happened more easily than level walking because of lots of environment facts need to be considered like the distance between user and stairs. One of the most important environment facts is recognizing of the stairs, therefore, to prevent the user from the danger in each situation, ultrasonic sensor is used as a safety system to keep space, and we called safety distance, between foot part of walking device and stair. The value of safety distance is not only defined as a switch to change the walking trajectory between the plain mode and the stair mode but also used to decide the ideal stride of trajectory while walking to stairs from even ground. Finally, the result of walking experiment shows that the safety walking experience by wearing our walking assistance device can be achieved.
UR - http://www.scopus.com/inward/record.url?scp=85028775386&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85028775386&partnerID=8YFLogxK
U2 - 10.1109/AIM.2017.8014122
DO - 10.1109/AIM.2017.8014122
M3 - Conference contribution
AN - SCOPUS:85028775386
T3 - IEEE/ASME International Conference on Advanced Intelligent Mechatronics, AIM
SP - 839
EP - 844
BT - 2017 IEEE International Conference on Advanced Intelligent Mechatronics, AIM 2017
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2017 IEEE International Conference on Advanced Intelligent Mechatronics, AIM 2017
Y2 - 3 July 2017 through 7 July 2017
ER -