Validation of accuracy of liver model with temperature-dependent thermal conductivity by comparing the simulation and in vitro RF ablation experiment

Hiroki Watanabe*, Nozomu Yamazaki, Yosuke Isobe, Xiaowei Lu, Yo Kobayashi, Tomoyuki Miyashita, Takeshi Ohdaira, Makoto Hashizume, Masakatsu G. Fujie

*この研究の対応する著者

研究成果: Conference contribution

7 被引用数 (Scopus)

抄録

Radiofrequency (RF) ablation is increasingly used to treat cancer because it is minimally invasive. However, it is difficult for operators to control precisely the formation of coagulation zones because of the inadequacies of imaging modalities. To overcome this limitation, we previously proposed a model-based robotic ablation system that can create the required size and shape of coagulation zone based on the dimensions of the tumor. At the heart of such a robotic system is a precise temperature distribution simulator for RF ablation. In this article, we evaluated the simulation accuracy of two numerical simulation liver models, one using a constant thermal conductivity value and the other using temperature-dependent thermal conductivity values, compared with temperatures obtained using in vitro experiments. The liver model that reflected the temperature dependence of thermal conductivity did not result in a large increase of simulation accuracy compared with the temperature-independent model in the temperature range achieved during clinical RF ablation.

本文言語English
ホスト出版物のタイトル2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2012
ページ5712-5717
ページ数6
DOI
出版ステータスPublished - 2012 12月 14
イベント34th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2012 - San Diego, CA, United States
継続期間: 2012 8月 282012 9月 1

出版物シリーズ

名前Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
ISSN(印刷版)1557-170X

Conference

Conference34th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2012
国/地域United States
CitySan Diego, CA
Period12/8/2812/9/1

ASJC Scopus subject areas

  • 信号処理
  • 生体医工学
  • コンピュータ ビジョンおよびパターン認識
  • 健康情報学

フィンガープリント

「Validation of accuracy of liver model with temperature-dependent thermal conductivity by comparing the simulation and in vitro RF ablation experiment」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル