TY - JOUR
T1 - Validation of droplet-generation performance of a newly developed microfluidic device with a three-dimensional structure
AU - Nozaki, Yoshito
AU - Yoon, Dong Hyun
AU - Furuya, Masahiro
AU - Fujita, Hiroyuki
AU - Sekiguchi, Tetsushi
AU - Shoji, Shuichi
N1 - Funding Information:
This work was partially supported by Canon Medical Systems Corporation, Japan . The authors also thank the MEXT Nanotechnology Platform Support Project of Waseda University for device fabrication.
Publisher Copyright:
© 2021 The Authors
PY - 2021/11/1
Y1 - 2021/11/1
N2 - We fabricated a microfluidic device with a three-dimensional (3D) structure and verified its droplet-generation performance for the stable production of droplets of around 10 μm in size. We compared the performance of the 3D device with that of conventional simple T-junction and cross-junction structures. The continuous phase sheared the dispersed phase into droplets from eight directions in the 3D device, compared with only one direction in the T-junction device and two in the cross-junction device. Droplets were produced efficiently over a wide range of fluid properties and flow conditions with the 3D device, unlike with the two conventional planar devices. Fluidic experiments were conducted using mineral oil with a surfactant as the continuous phase, deionized (DI) water as the dispersed phase, and DI water with glycerin to change the viscosity of the dispersed phase. The minimum droplet length was 47.2 μm in the T-junction device, 39.0 μm in the cross-junction device, and 22.4 μm in the 3D device when using a water and glycerin mixture with a viscosity of 9.0 mPa·s. Compared with the conventional devices, smaller droplets were produced using our 3D device, indicating that it has excellent droplet-generation performance.
AB - We fabricated a microfluidic device with a three-dimensional (3D) structure and verified its droplet-generation performance for the stable production of droplets of around 10 μm in size. We compared the performance of the 3D device with that of conventional simple T-junction and cross-junction structures. The continuous phase sheared the dispersed phase into droplets from eight directions in the 3D device, compared with only one direction in the T-junction device and two in the cross-junction device. Droplets were produced efficiently over a wide range of fluid properties and flow conditions with the 3D device, unlike with the two conventional planar devices. Fluidic experiments were conducted using mineral oil with a surfactant as the continuous phase, deionized (DI) water as the dispersed phase, and DI water with glycerin to change the viscosity of the dispersed phase. The minimum droplet length was 47.2 μm in the T-junction device, 39.0 μm in the cross-junction device, and 22.4 μm in the 3D device when using a water and glycerin mixture with a viscosity of 9.0 mPa·s. Compared with the conventional devices, smaller droplets were produced using our 3D device, indicating that it has excellent droplet-generation performance.
KW - Capillary number
KW - Droplet generation
KW - Microdroplet
KW - Three-dimensional device
KW - Viscosity
UR - http://www.scopus.com/inward/record.url?scp=85108956129&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85108956129&partnerID=8YFLogxK
U2 - 10.1016/j.sna.2021.112917
DO - 10.1016/j.sna.2021.112917
M3 - Article
AN - SCOPUS:85108956129
SN - 0924-4247
VL - 331
JO - Sensors and Actuators, A: Physical
JF - Sensors and Actuators, A: Physical
M1 - 112917
ER -