Validation of the fire safety performance of local wall clay compound in kyoto district

Hiroki Ozawa*, Yuji Hasemi, Noboru Yasui, Yoshihide Tamura, Masashi Yoshida, Naoyuki Koshiishi, Tsuneto Tuchihashi

*この研究の対応する著者

研究成果: Article査読

抄録

The clay wall, unapproved as a fire-protective material in Building Standard Low, has a problem of the building confirmation. Therefore, clay wall is required to be analyzed on its fire-protective performance. Since clay contains a certain amount of organic substances, it has a probability of combustion and heat releasing. This paper reports the fireprotective ability of wall clay, examining through the cone calorimeter and the gas toxicity, utilized as a means of the approval tests for fireprotective material have been carried out. As a result, the wall clay, even enriched straw, proved that it has a performance of noncombustible matter.

本文言語English
ページ(範囲)219-224
ページ数6
ジャーナルAIJ Journal of Technology and Design
18
38
DOI
出版ステータスPublished - 2012

ASJC Scopus subject areas

  • 建築
  • 建築および建設